Lochinvar water heater error codes

All KNIGHT fire tube boilers allow for flexible installation with a universal vent connector. Range in heating capacity from 55,000 to 399,000 Btu/hr and perform at 95% AFUE efficiency. The KNIGHT's Smart System™ display includes the CON•X•US® Remote Connect option to maintain control of your boiler from anywhere.

Lochinvar water heater error codes. This natural gas water heater comes with a 3-inch water vet with an overall rating of 95% AFUE. According to the manufacturer, this product can deliver 4.8 gallons of heated water per minute. Additionally, it comes with a 10:1 turndown ratio making its heating capacity just ideal for residential use.

PRINTED 1215 322886-005. PLACE THESE INSTRUCTIONS ADJACENT TO HEATER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE. COMMERCIAL ELECTRIC WATER HEATERS. Thank you for buying this energy efficient water heater. We appreciate your confidence in our products. MODELS HS 50/80/119 Series 100 & HC 50/80/119 Series 100.

ARMOR Condensing Water Heater. With ten models from 400,000 to 4,000,000 Btu/hr input, ARMOR will service a large range of commercial applications and add the "green" touch that building owners and facility managers desire. 10 Models from 400,000 to 4,000,000 Btu/hr. Up to 99% Thermal Efficiency.Note: Never exceed the maximum recommendation flow rate for the connecting pipe. And remember, you must ensure that the water flow is not obstructed. It's possible that there's air in the pipes. Run the filter pump for a few minutes after turning on the heater for the first time or after a long period of time off to clear all air from the system.Installation Commissioning and Maintenance Instructions - LochinvarLochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 | F: 615.547.1000 Lochinvar.com @ GPH Ship Model Btu/hrCapacity Thermal100° 1st Gas Water Air VentWgt. Number Input (Gals.) Eff. Rise Hour A B D E F Conn. Conn. Inlet Size (lbs.) Regular Construction This video covers the repair of the leaking union above the pump on the lockinvar commercial water heaters .#plumbing #water heater #commercial water heater View and Download Lochinvar 100 Series installation & service manual online. Indirect Plate Water Heater. 100 Series water heater pdf manual download. Also for: Ipw120dw, Ipw015dw, Ipw090dw, Ipw070dw, Ipw105dw, Ipw030dw, Ipw050dw.Whirlpool washers are known for their reliability and efficiency in cleaning clothes. However, like any other appliance, they can sometimes encounter issues that may result in erro...

How much does it cost to replace a 40-gallon water heater? It costs you between $400-$900 to replace a new 40-gallon water heater if it comes with a tank. On the other hand, a tankless water heater will take around $1470-$2510. Conclusion. From the beginning to the end, we have discussed Vaughn water heater problems and the reasons behind them.Lochinvar Copper-Fin II CFN0752 Installation And Operation Manual (80 pages) Lochinvar Water Heater User Manual. Brand: Lochinvar | Category: Water Heater | Size: 7.97 MB.Page 29 1 Turn the power off for 10-20 seconds, then on again to Self diagnostic check has detected clear these error codes. a problem with the gas valve driver circuit, internal microprocessor, or 2 If any of these …For nearly 80 years, Lochinvar, an American company, has been a leader of innovation and high-efficiency water heating. Through Lochinvar's pride in leadership and commitment to excellence, the company has continually improved year after year. Today, Lochinvar touts the broadest line of high-efficiency water heating solutions, a world-class ...Replace the main control board. Revision Notes: Revision A (ECO #C11226) initial release to reflect the new manual name and removal of the pool heater information. Revision B (ECO C11706) reflects the update of information with the “SH Controlling Sensor (boiler only)” section on page 22. CFX-CHX-SER Rev B.July 2014. Hello, I have a Lochinvar Shield Commercial Water heater giving me problems. Model SNA400-125, installed three years ago. It keeps locking out on manual reset high limit when demand is at its lowest at night. I have replaced the inlet and outlet temperature sensors, problem still there. Doent happen every night, it will run good ...AFR rods monitor the air fuel ratio of your water heater's internal combustion engine, which is a massively important part of your water heater's function. However, damage and soot can sometimes prevent the AFR rod from doing its job properly and it requires attention.

Lochinvar LLC 300 Maddox Simpson Pkwy, Lebanon, TN 37090. 1-615-889-8900 www.lochinvar.com Lochinvar Parts & Service Department 300 Maddox Simpson Pkwy, Lebanon, TN 37090. Phone: 615-889-8900 • Fax: 615-882-2918 Email: [email protected] Corporation is a leading manufacturer of high-efficiency water heaters, boilers, pool heaters and storage tanks. Based in Lebanon, TN with facilities in Detroit, Orlando, Tampa, Pompano Beach and Dallas, Lochinvar stocks all products in all locations. For media inquiries, please contact Emily Towey at (312) 946-6143 or [email protected] AND SERVICE MANUAL. GAS HEATERS FOR COMMERCIAL POOL APPLICATIONS 500,000 - 2,070,000 Btu/hr MODELS Starting Serial #F0600187510. CPE-I-S-14. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.View and Download Lochinvar LTN07575 instruction manual online. RESIDENTIAL GAS WATER HEATERS. NOT FOR USE IN MANUFACTURED (MOBILE) HOMES. LTN07575 water heater pdf manual download. Also for: Ltn10075, Ltl07575st, Ltn10075st, Ltl10075st, Ltl07575, Ltl10075, Ltn07575st.The Harmony can be equipped to operate up to four 0-5 V, 0-10V, 1-5V, or 2-10V modulating motors. Apply the supplied label marked Voltage below the output terminals. The output boards are connected on the rear of the panel. To select the range, 0-5V, 0-10V, 1-5V or 1-10V, see pg. 12.Fix or replace the water heater thermostat. 4. Descale the water heater. 5. Fix or replace the faulty pressure valve. The first step to solving any water heater issue, including the beeping noise, is to detect the core issue. Here are some of the most common problems that could be causing your water heater to beep. 1.

Diy butterfly money lei.

Hot Water Solutions Since 1939 | Lochinvar | LochinvarTurn the main power switch to the "OFF" position. Shut off gas supply at the field installed manual gas cock in the gas piping to the appliance. If fuel supply is LP gas, shut off gas supply at the tank. On ER152 - ER202 models remove the 1/8" hex plug, located on the "inlet" side of the gas valve.Have this water heater serviced/inspected by a qualified service technician at least annually. Failure to comply with the above could result in severe personal injury, death or substantial property damage. When calling or writing about the water heater – Please have the water heater model and serial number from the water heater rating plate.Multi-Flue Charger commercial gas water heaters are designed to provide ease of installation, low stand-by loss, and years of trouble-free service. 13 Models from 65 to 100 Gallons Gas Inputs from 120,000 to 500,000 Btu/hr

STATUS LIGHT AND DIAGNOSTIC CODE TROUBLESHOOTING CHART (Continued) LED STATUS PROBLEM CORRECTIVE ACTION 4 FLASHES The Gas Control Valve’s Relight pilot and verify 4 flashes. If 4 flashes are temperature sensor has detected observed, turn Gas Control Valve/Thermostat knob that the water temperature was to OFF.Code, CAN/CGA-B149.1 and/or B149.2 and/or local codes. This appliance meets the safe lighting performance criteria with the gas manifold and control assembly provided, as specified in the ANSI standards for gas-fired units, ANSI Z21.13. 1. Locate the appliance so that if water connections should leak, water damage will not occur. When such ...Lochinvar Copper-Fin II CFN0992 Installation And Operation Manual (80 pages) Lochinvar Water Heater User Manual. Brand: Lochinvar | Category: Water Heater | Size: 7.97 MB.Download 1048 Lochinvar Water Heater PDF manuals. User manuals, Lochinvar Water Heater Operating guides and Service manuals.Yeah, there are different controls depending on the unit age. whats happening is the supply sensor is raising temp to quickly. cause is slow water flow most likely. or if you have motorized isolation valves not opening enough. which is also creating a low flow situation. the supply sensor is a dual sensors. S1 and S9.Boiler Lochinvar 45,000—500,000 Btu/hr Models Installation And Service Manual Water heater/domestic hot water supply boiler (48 pages) Boiler Lochinvar Copper-Fin 497 User's Information ManualLack of power to the fan: Ensure that the fan motor is receiving the necessary electrical power. Check the voltage on the fan wiring connection (black and yellow wires) to confirm if power is being supplied. Wet fan connector: Inspect the fan connector to check for any moisture. If the connector is wet, turn off the unit and dry the fan connector …I have a Lockinvar Hot water Boiler model #1. CHN1802 getting a fault code HSI Lockout Current LOWA? Is this a low water condition as the boiler keeps running.2. Water set point moved from 160 to 140 … read moreThis manual must remain with the water heater. INSTALLATION - OPERATION MAINTENANCE - SERVICE - TROUBLESHOOTING. If the water heater becomes immersed in water up to or above the level of the bottom of the element doors, the heater should be examined by a qualified service agency before it is placed in operation. Electrical Shock Hazard.2. Allow time for the water heater to cool to room temperature if it has been firing. Page 58: Troubleshooting F2 - 3.15 AMP FUSE 24V SUPPLY 5. The water heater is shipped with three (3) spare fuses in a plastic bag attached to the control module cover. 6. If necessary, replace open fuse (F3 is 1.25 amps, F2 and F4 are 3.15 amps, and F5 is 5 amps).

Replacement Parts List. PARTS & SERVICE DEPARTMENT. Nashville, Tennessee 615-889-8900 • Fax: 615-882-2918 [email protected] www.Lochinvar.com.

Hot Water Solutions Since 1939 | Lochinvar | LochinvarThis Lochinvar water heater makes it to our list as a runner-up because of its high-quality construction. It has a high water storage capacity, decreasing the need for recirculation. This also helps you have a consistent supply of hot water once it gets full. The storage capacity of 75 to 100 gallons is also quite impressive.DOMESTIC WATER HEATERS 495,000 - 2,065,000 Btu/hr MODELS CB-CW(E)-I-S-07. Hydronic Heating Boilers and Domestic Water Heaters 2 Table of Contents ... Gas Code, ANSI Z223.1 and/or CAN/CGA-B149 Installation Code. Where required by the authority having jurisdiction, theWe are a leading producer of energy-efficient water heating solutions that are radically simple, brilliantly engineered and perfectly suited for most any application. We focus solely on serving the unique needs of each customer with a product portfolio including boilers, water heaters, pool heaters, cogeneration products and commercial package ...Faulty gas control valve; Clogged vent, etc. Solution. If insufficient gas supply is the problem, you need to make sure the gas tank valve is open so that it can supply gas without interruption.I have a RUUD PVP50F natural gas power vent hot water heater. It seemed to be working fine yesterday, but today it was flashing a code that indicates "flame lost." Probable causes (in the manual) are, … read moreLochinvar® Water Heater & Boiler age. How to determine the date of production/manufacture or age of Lochinvar® brand Water Heater & Boiler Systems. Water heaters in general have an average estimated useful service life of 10-12 years, though water quality, routine upkeep/maintenance, and location of the water heater will all play critical ...EcoCharger is a range of fully condensing, gas-fired, floor-standing, storage water heaters. These water heaters have low NO x emissions and can achieve efficiencies up to 98.0% gross CV and can help reduce energy use & carbon emissions. The range is suitable for a wide variety of commercial and industrial water heating applications.We have 1 Lochinvar ARMOR 501 manual available for free PDF download: Service Manual Lochinvar ARMOR 501 Service Manual (41 pages) Lochinvar Water Heater User Manual

Iphone amiibo emulator.

On the run rylo.

Knight gas-fired, floor-standing, storage water heaters can achieve efficiencies up to 79% gross CV. These water heaters are designed on the principles of low storage and fast recovery, and when compared to indirect hot water systems, they can achieve savings on energy consumption & carbon emissions. 5 models suitable for Natural Gas or LPG.Yeah, there are different controls depending on the unit age. whats happening is the supply sensor is raising temp to quickly. cause is slow water flow most likely. or if you have motorized isolation valves not opening enough. which is also creating a low flow situation. the supply sensor is a dual sensors. S1 and S9.The Lochinvar 35-50 Series gas fired, tank type water heaters are designed to provide ease ... standards. Meets UBC, CEC and ICC National codes. Meets thermal efficiency and standby loss requirements of the U.S. ... SWN150-035 is classified as an instantaneous consumer water heater and receives a 4.2 Maximum Gallon per Minute (GPM) rating. ...• describe the working principles and layout of the water heater • explain the safety devices • highlight possible hazards • describe the use of the water heater • describe the installation, service and maintenance of the water heater This manual has two parts: • An User part that describes the correct usage of the water heater.SKU: 100208243. $5525 $6500 Save $9.75. Part Number 100208544 Lochinvar Outlet Sensor / High Limit (Controls) SKU: 100208544. $3230 $3800 Save $5.70. Part Number 100165923 Flame Sensor with gasket for FTX. SKU: $6120 $7200 Save $10.80. Part Number 100165924 Ignitor W gasket for FTX.CommerCial gas water heaters instruction manual PRINTED 1112 324478-000 plaCe these instruCtions adjaCent to heater and notify owner to keep for future referenCe. Thank you for buying this energy efficient water heater. We appreciate your confidence in our products. models Cln120080, Cln154080, Cln180100, Cln199100, Cln250100(a) ultra low nox ...LG dishwashers are known for their reliability and efficiency in getting your dishes clean. However, like any appliance, they can sometimes encounter issues that result in error co...View and Download Lochinvar 502 service manual online. Copper-fin II/IIE Pool Heater. 502 swimming pool heater pdf manual download. Also for: 2072, 502-752, 992-2072.Replace the main control board. Revision Notes: Revision A (ECO #C11226) initial release to reflect the new manual name and removal of the pool heater information. Revision B (ECO C11706) reflects the update of information with the “SH Controlling Sensor (boiler only)” section on page 22. CFX-CHX-SER Rev B.Power Direct Vent Residential Gas Water Heater. Available in 40, 50 and 75 gallon capacities, the models feature a power direct vent system for sidewall or rooftop termination and are qualified for ENERGY STAR. Power Direct Vent Models from 40 to 75 Gallons. Gas Inputs from 40,000 - 72,000 Btu/Hr. Glass Lined Steel Tank with Protective Anode Rod.View and Download Lochinvar LTN07575 instruction manual online. RESIDENTIAL GAS WATER HEATERS. NOT FOR USE IN MANUFACTURED (MOBILE) HOMES. LTN07575 water heater pdf manual download. Also for: Ltn10075, Ltl07575st, Ltn10075st, Ltl10075st, Ltl07575, Ltl10075, Ltn07575st. ….

The First Name in Efficiency. CREST boilers are equipped with a top-mounted micro-metal fiber burner, engineered specifically for fire-tube technology. The system is designed to ensure smooth, quiet modulating combustion with up to 25:1 turndown. CREST is designed for efficiency to reduce your customer's fuel bills.Temperature range on residential gas water heater is from 110°F ±10° to 155°F ±10° and a 70°F vacation setting. The T&P valve will open at 195°F ± 10°. The water heater temperature adjusting dial is factory set at the lowest temperature, all the way counter-clockwise to the mechanical stop, unless specified differently by provincial orView and Download Lochinvar Innovo installation, user and service manual online. Condensing High Efficiency Water Heater. Innovo water heater pdf manual download. Also for: Ir 12-160, Ir 12-200, Ir 20-160, Ir 20-200, Ir 24-245, Ir 24-285, Ir 32-245, Ir 32-285, Ir 32-380.The Lochinvar Charger gas-fired, tank-type water heaters are designed to provide ease of installation, low stand-by loss and years of trouble-free service. Chargers are ideally suited ... Charger water heater. It has standard construction, 180,000 Btu/hr, and 81 gallon storage capacity. Charger Gallon Capacity Natural GasDVN03-08 Residential Gas Power-Vented Models DVN & DVL 041 & 051 5 3 2 16 19 15 13 6 14 17 18 9 9 8 20 10 21 11 11 12 PARTS & SERVICE DEPARTMENT Nashville, TennesseeLochinvar Swimming Pool Heater User Manual. COPPER-FINN2 2072 swimming pool heater pdf manual download. ... technicians, or gas suppliers. Consult and follow all local Building and NOTICE Fire Regulations and other Safety Codes that apply to this installation. ... Water connections Figure 4-3_Heater Within 15 feet of Pool Piping MODEL NO BYPASS ...Tankless Water Heater Video Tutorials. INSTALLATION (1:16:16) This video demonstrates installation of a tankless water heater. ... TROUBLESHOOTING: ERROR CODE 111 …Lochinvar GTN05040 Energy Saver Tall Natural Gas Water Heater, 50 GAL, 40000 BTU/HR. Can't find a product? Call now! 888-756-4110 Cart (0) Items ... AHRI Certified, CSA Low Lead Content Certified, NAECA Compliant, ASHRAE/IES 90.1. Meets UBC, CEC and HUD National Codes Our energy saver residential gas water heaters deliver from 35000 - 60000 BTU ... Lochinvar water heater error codes, Fortunately, most Lochinvar water heaters have a reset button on the thermostat. If not, you can always perform a hard reset of the whole device by flipping the breaker or unplugging it from the outlet. This post will explore which models of Lochinvar have reset buttons, how to perform a hard reset, and what you can explore if a reset fails., Use a flathead screwdriver to remove the access panel at the front area of the heater. Next, remove the insulation. Once you do that, you will find a red button. And that is the reset button of the Richmond tankless water heater. Press the red button to reset the unit., The Lochinvar SDT/SET series indirect water heater (FIG. 1-1) is designed to generate domestic hot water in conjunction with a solar panel using forced circulation with a backup heat source. This indirect water heater consists of a 316L Stainless Steel tank in which a smooth 316L stainless steel coil is located (Table 1A)., 8. Once the combustion analysis is complete, test the safety shutoff device by turning the manual shutoff switch to the OFF position and ensuring that the boiler shuts down and registers an alarm. Turn the manual shutoff switch to the ON position, reset the control, and return to Service Mode. 9., Download service manual for Lochinvar 2072, 402. Learn more about Troubleshooting, Fault, Description, Corrective Action, No Flame Ign, HSI Current Low, Flame CKT, …, Freeze protection pump on. In order to prevent the water in the heater from freezing, the SMART SYSTEM control turns on the boiler pump whenever the inlet temperature goes below the minimum temperature. The range of this parameter is 32°F (0°C) to 104°F (40°C). The default value is 45°F (7°C)., with water heater. warning all technical and warranty questions: should be directed to the local dealer from whom the water heater was purchased. if you are unsuccessful, please contact the company listed on the rating plate on the water heater. 300 maddox simpson parkway lebanon, tn 37090 phone: 615-889-8900 • fax: 615-547-1000, pool and spa heater, for homeowners who want the best of everything. Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com 10/2023 - Printed in U.S.A. HLW Optional ERP-05 (Reprint ERP-05 5/22) ® For technical information call 800-722-2101. Lochinvar, LLC reserves the, Place the communication board onto the standoff s installed in Step 3. Use the screw (provided in kit) to secure the control panel cover (FIG. 2-6). 5. Connect the wire harnesses (100172824 , 100172826 and 100172828) from the appliance to the communication board following the diagram shown in FIG. 2-7. 6., Introducing Lochinvar's XCalibur premium condensing gas tankless water heaters, delivering robust, on-demand performance and the flexibility to install in practically any residential setting. 3 Models: 160, 180 & 199 MBH. X3® Scale Prevention., Product. Lochinvar has updated its residential gas and electric water heaters in conjunction with the new minimum efficiency requirements from the National Appliance Energy Conservation Act and the U.S. Department of Energy. Effective April 16, 2015, all residential water heater manufacturers must meet the NAECA III efficiency requirements., The outlet water temperature has exceeded the 210°F manual reset high limit (MRHL) setting. • Verify that the system is full of water and that all air has been …, The data plate also includes a QR code, providing easy access to product information for Service Engineer(s). EcoSword water heater 9 models Lochinvar EcoSword water heaters EcoSword fully condensing gas-fired water heaters are available in 9 models, with storage capacities ranging from 163 to 388 litres and hot water recovery rates from , National Standard Code C22.2, No. 110-M90. This water heater must be installed in accordance with local codes. In the absence of local codes, install this water heater in accordance with the latest edition of the National Electrical Code. The warranty for this water heater is in effect only when the water heater is, Installation Commissioning and Maintenance Instructions - Lochinvar, Copper-Fin II® Water Heaters. In 1993, Lochinvar introduced the first horizontal chassis, copper-finned tube water heater with fan-assisted combustion. 9 Models from 400,000 - 2,070,000 Btu/hr. 85% thermal efficiency. 4:1 Turndown Ratio. Gasketless Copper-Finned Tube Heat Exchanger. SMART SYSTEM™ Operating Control with a Built-in Cascade ..., Temperature range on residential gas water heater is from 110°F ±10° to 155°F ±10° and a 70°F vacation setting. The T&P valve will open at 195°F ± 10°. The water heater temperature adjusting dial is factory set at the lowest temperature, all the way counter-clockwise to the mechanical stop, unless specified differently by provincial or, Fortunately, most Lochinvar water heaters have a reset button on the thermostat. If not, you can always perform a hard reset of the whole device by flipping the breaker or unplugging it from the outlet. This post will explore which models of Lochinvar have reset buttons, how to perform a hard reset, and what you can explore if a reset fails. , Freeze protection pump on. In order to prevent the water in the heater from freezing, the SMART SYSTEM control turns on the boiler pump whenever the inlet temperature goes below the minimum temperature. The range of this parameter is 32°F (0°C) to 104°F (40°C). The default value is 45°F (7°C)., Any time an error, fault or function code is displayed, service will be required. Please Note: Any failure of the heat pump will result in an automatic switch to the resistance heat mode to ensure a constant supply of hot water. For service and support on the GeoSpring Hybrid Electric Water Heater, please contact 1-888-443-4394, Monday - Friday ..., The SHIELD commercial gas water heater is a complete water heating system beautifully packaged in a small footprint. 10 models from 125,000 to 500,000 Btu/hr. Up to 96% Thermal Efficiency. Longer Vent Runs - 150 ft. Exhaust and 150 ft. Air Intake. BMS Integration with BACnet and Modbus. , The Water Heater requires a service, particularly around the pilot assembly. ... • If the appliance is one of Lochinvar's • Which electronics package and model it is ... Enter the code 5309 using the DIAL scan through the numbers and pushing the dial to accept correct number;, Yeah, there are different controls depending on the unit age. whats happening is the supply sensor is raising temp to quickly. cause is slow water flow most likely. or if you have motorized isolation valves not opening enough. which is also creating a low flow situation. the supply sensor is a dual sensors. S1 and S9., This video covers the repair of the leaking union above the pump on the lockinvar commercial water heaters .#plumbing #water heater #commercial water heater , Key features. Recovery rates from 844 to 1,453 litres/hour. Output range from 49.1 to 84.4 kW. New low NO x burner design. Available from stock. Choice of draught diverters enables easy replacement (click on the drawings on the left for more details) Up to 8 bar working pressure. Low NO x emissions ≤ 45mg/kWh. Small footprint., Lochinvar DESIGNER'S GUIDE COPPER-FIN WATER HEATER615-889-8900 5 COMBUSTION & VENTILATION AIR Provisions for combustion and ventilation air must be in accordance with Section 5.3, Air for Combustion and Ventilation, of the latest edition of the National Fuel Gas Code, ANSI Z223.1; in Canada, the latest edition of CGA Standard B149 Installation ..., Feb 11, 2023 · Lochinvar Shield SNR126-065 boiler troubleshooting. - No 120 VAC supplied to unit. • Check external line switch, fuse, or breaker. • Check wiring harness connection between display board and main control board. Connect harness at both points. • Bad display board. • Replace board. - Bad main control board. • Replace the main control board. , Turn the main power switch to the "OFF" position. Shut off gas supply at the field installed manual gas cock in the gas piping to the appliance. If fuel supply is LP gas, shut off gas supply at the tank. On ER152 - ER202 models remove the 1/8" hex plug, located on the "inlet" side of the gas valve., Product by Lochinvar Marketing Department | 08/08/2023. Lochinvar, an industry leader in high efficiency boilers and water heaters, announces the Veritus™ Air Source Heat Pump Water Heater.Raising the bar on energy efficiency and simplifying installation and operation, the Veritus Heat Pump Water Heater (HPWH) serves as a sustainable option providing energy savings and reliable domestic hot ..., Aug 19, 2020 · Replace defective gas control. When thermocouple tip is not in contact with pilot flame, insert it properly. 7. Insufficient Hot Water. Follow lighting instructions correctly – lit heater and turn on the thermostat. Regulate the temperature to desired heat. Allow more time to heat water. , Lochinvar Manuals; Water Heater; ARMOR 501; Lochinvar ARMOR 501 Manuals Manuals and User Guides for Lochinvar ARMOR 501. We have 1 Lochinvar ARMOR 501 manual available for free PDF download: Service Manual ... Water Heater Boiler Gas Heater Swimming Pool Heater Heat Pump. More Lochinvar Manuals, Is your water heater showing a flammable vapor sensor code? Luckily that error code can easily be reset and you will have hot water again in less then an hou..., COMMERCIAL WATER HEATERS. CLD-09 ... 9/22 - Printed in USA DIMENSIONS & SPECIFICATIONS Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com For technical information call 800-722-2101. Lochinvar, LLC ... See "Element Availability Schedule" for letter codes …