Check the Gas Valve. Start by ensuring that the gas valve is open and allowing the flow of gas to the pool heater. If the gas valve is closed or partially closed, the heater won’t receive the necessary fuel to ignite. Make sure the valve is fully open and functioning correctly.

Hayward heater if code. CE code indicates "Communication Error". Problem is communication between integrated control board and display board. Display board (DB) is the ...

Remove front & rear panels Remove wires from limit switches. Step 13. Remove the 4 screws from the bottom of the front and rear panels and pull up and out to remove each one. Step 14. Use needle nose pliers to remove the 2 red wires from each of the high limit switches. Remove wires from water pressure switch.

My heater is a Hayward pool heater. I was sitting by the pool and all of a sudden there was a loud banging sound, I ran over to the heater and turned it off. The code that was displayed was H5. … read moreUniversal HC Series - Dual Fuel 400k BTU. Hayward. SKU: HDF400. The industry's smallest footprint heater allows replacement of almost any heater in an existing pad with the efficient reliability of the new Universal HC Series dual-fuel technology heater from Hayward®. Add to Compare. Add to Export. Overview.Dec 13, 2023 · LO CODE FIXES. Step 1: Inspecting the Water Pressure Switch Wiring. Step 2: Testing Water Pressure Switch Continuity. Step 3: Pressure Switch Adjustment (If Required) Step 4: Temperature Limit Switch Wiring Inspection. Step 5: Continuity Test for Temperature Limit Switches. View online or download PDF (6 MB) Hayward H250FD, H350FD, H300FD, H150FD, H400FD, H200FD, Universal H-Series Low NOx User manual • H250FD, H350FD, H300FD, H150FD, H400FD, H200FD, Universal H-Series Low NOx above ground pool accessories PDF manual download and more Hayward online manuals.PitschPlumbing. Generally, LO refers to the pressure switch, water pressure. This can be caused by either the diaphram in the flow switch has failed or the filters is clogged and/or pump is unable to make enough pressure to make the switch. Open the front panel of the heater and look up in to the right. You will see a round part with 2 wires ...Hayward H150FDN Troubleshooting Manual. Universal h series heaters. Also See for H150FDN: Service & installation manual (64 pages) , Owner's manual (16 pages) 1. 2. Table Of Contents. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26.The Hayward Universal H-Series gas heater is one of the most energy-efficient Pool and Spa heating solutions on the market! Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx capabilities.

The Hayward Heater HS code indicates that either your water temperature has exceeded a maximum of 104°F or the water temperature is changing at an unusual rate (faster than 6°F in 60 seconds or less while the heater) is on and firing.USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 1002785 RevA Hayward Industries 1415 Vantage Park Dr., Suite 400 Charlotte, NC 28203 Phone: (908) 355-7995 ... Note that the filter pump, heater/chiller, lights and chlorination will continue to run if scheduled. Simple Mode (page 33) - Simple Mode is a customizable screen that can be set up for quick ...May 25, 2022 · You need to put the heater in STANDBY Mode to get the bO code on the heater display. Press the mode button once to get the heater in STANDBY Mode. First, press and hold on to the Down key. Then, press and hold down the MODE key as well. You need to keep holding both keys for about three seconds. At this point, the “bO” message should appear ... View online or download Hayward H250FDN Owner's Manual, Troubleshooting Manual ... Brands; Hayward Manuals; Heater; H250FDN; Hayward H250FDN Manuals. Manuals and User Guides for Hayward H250FDN. We have 6 Hayward H250FDN manuals available for free PDF download: Troubleshooting ... Diagnostic Codes and Part Numbers. 19. …Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support. ... Phase Heaters: 1.0000: Pool Type: In Ground: Product Dimensions: 24 " x 34 " x 29.5 "Product Height: 24 in: Product Length: 29.5 in: Product Weight: 195 lb: Product Width:

2 Troubleshooting Steps. 2.1 Check Gas Pressure And Fuel Supply. 2.2 Inspect Air Supply And Venting. 2.3 Ensure Proper Water Flow. 2.4 Clean Filters And Pump. 2.5 Adjust External Bypass If Needed. 3 Tips For Diagnosing Problems. 3.1 Follow The Heater Start Sequence. 3.2 Refer To The Diagnostic Codes Manual.USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 51300102101 RevB Hayward Industries 1415 Vantage Park Dr., Suite 400 Charlotte, NC 28203 Phone: (908) 355-7995 www.hayward.com ... Conformance With Codes: The heater shall be installed in accordance with all local and state codes and with theThe gas pressure to the Pentair pool heater often gets obstructed due to clogged gas pipes, incorrect pressure settings, and turned off gas valves. These factors prevent the gas from reaching the heater and performing properly. It also causes the heater to shut down completely and display the E05 code on the Pentair heater.Learn How Solar Pool Heaters Work; Learn About Hayward. At Hayward, we're more than just equipment. Learn more. Hayward Insights. Hayward Insights. Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support.

Hbo max adventure time missing episodes.

Hayward ID Tag that will replace our current serial number system. To the left is an explanation of how to read this number. This ID tag will also list the model number. * Early 1-05 Heat Pumps, Heaters*, Filters, Pumps p, , , p Starting May 1, 2010 and Forward (21) 12-1004-000002006 The 5th -6th number will be the year & theWhat Is My Hidden Talent. Flat Creek Lodge Hayward. 10290 Highway 27 South, Hayward, WI 54843.Enter Dates. From $135. Check In. 15 00. Check Out. 15 00.. Browse and compare Hayward motels when you search with Expedia. Read reviews, search by map, and book the best motels in Hayward that suit your needs with Expedia.ca. "/> . 14.Flame sensor rectifies presence of flame through ground ...i puchased a hayward h-series 100,000 btu natural gas heater 8/24/2012 only used it about 2 times in fall and it worked fine. LAST WEEKEND 03/15/13 I RAN FOR ABOUT 24 HOURS AND IT WORKED GREAT WENT TO …Hayward 150 heater through an AO code which often means a blower switch. This was $28 and super easy to install. Seriously, I've been more difficulty plugging Lampson to outlets and changing the switch. Seriously, I've been more difficulty plugging lamps into outlets than changing this switch.Fixed our problem for less than $30.

Many choose Hayward pool heaters to keep their pool water comfortable and warm. However, sometimes these heaters can experience issues that require a reset. To reset your Hayward pool heater, you'll need to turn off the power, wait a few minutes, and then turn it back on again. This simple process can resolve many common […]hayward pool heater HD1001D1 will heat for 5 seconds then stops. I have jumped aroune the two sensors on the water line and still operates the same. The thermostat and igniter have been replaced and s …Mar 24, 2023 · Turn off your heater, wait a few minutes, then power it back on. If the AO Code persists, move on to the next step. Check the wiring: Inspect the wiring between the blower vacuum switch and the control board. Look for loose connections, damaged wires, or other signs of wear and tear. If you spot any issues, call a professional for assistance. That's the one. I haven't been on site yet. Not sure if it's going to be a board, sensor, short, or blockage. Those are the only causes I can think of.Make sure that the heater is in POOL or SPA mode. Press the MODE button on the user panel keypads to set the heater on STANDBY mode. On STANDBY mode, the heater will not heat the water. Press and hold the MODE and DOWN buttons for at least three seconds. The panel should display BO, which means bypass operation.The Hayward Pool Heater SF Code is a safety feature that prevents the pool heater from over-heating. The code stands for "Safety Fault" and is displayed when the temperature in the heater exceeds 110 degrees Fahrenheit (43°C). It will shut off power to the pool heater until it can cool down to a safe temperature.April 9, 2023 by William. Hayward pool heater IF code basically signifies the ignition failure of your heater system. The major reasons for Hayward pool heater code IF/ignition failure include lower gas supply, clogged filter, and malfunctioning of the gas and plumber valve. Also, a faulty transformer, defective flame sensor, bad igniter, and ...For Canadian installations, the heater must be installed in accordance with standards CAN/CGA B149.1 and B149.2 - INSTALLATION CODES FOR GAS BURNING APPLIANCES AND EQUIPMENT and/or local codes, and if applicable, Standard CSA C22.1 - CANADIAN ELECTRICAL CODE, Part 1. Location of heater: Locate the heater in an area where a leaking heatThe major reasons for Hayward pool heater code IF/ignition failure include lower gas supply, clogged filter, and malfunctioning of the gas and plumber valve. Also, a faulty transformer, defective flame sensor, bad igniter, and incorrect thermostat temperature setting are the root.

Hayward 150 heater through an AO code which often means a blower switch. This was $28 and super easy to install. Seriously, I've been more difficulty plugging Lampson to outlets and changing the switch. Seriously, I've been more difficulty plugging lamps into outlets than changing this switch.Fixed our problem for less than $30.

Having problem again with our Hayward H350FDN Pool Heater. Code display 1st was BD and now we are getting code CE. Checked continuity of plug and ribbon wire both OK. What other test can I perform to … read moreHayward H250 pool heaters can experience ignition failure due to a variety of reasons. Possible causes include: faulty electrical connections, a failed thermistor or Hi-Limit switch, an obstructed flue vent pipe, and/or debris in the combustion chamber. If the heater fails to ignite when it is turned on, first check that power is being supplied ...The hs code for hayward pool heaters is the classification number assigned to these products for international trade purposes. Hayward pool heaters fall under hs code 8419. Consequently, this code is used to facilitate smooth customs clearance and to ensure accurate tracking of imports and exports of these products globally.Hayward Pool Products 620 Division Street, Elizabeth NJ 07207 Phone (908)-355-7995 www.hayward.com ... heater, a valve actuator, pool and yard lighting, and more. The VS Omni offers the next generation of ... local codes require). The Hub is designed to mount vertically with the knockouts facing View and Download Hayward H250FDN service & installation manual online. POOL AND SPA/HOT TUB HEATERS. H250FDN heater pdf manual download. Also for: H250fdp, H350fdn, H350fdp, H400fdn, H400fdp. The following 6 California counties are affected: Los Angeles, San Bernardino, Ventura, Orange, Riverside, and Kern. Installing a non-compliant heater in these counties will void the manufacturer's warranty and could result in a fine from your local code enforcement. Item cannot be refunded/returned without approval and authorization from Home ...By carefully following these steps and additional advice, you should be able to effectively diagnose and resolve the AO code issue on your Hayward heater. Have a question about pool heaters? Airlucent owner Tim David would like to answer your question in an upcoming article, call (256) 399-9708 or contact David via the contact page .

Does nair help with strawberry legs.

Century 25 showtimes orange ca.

FAQ: What are the Hayward pool heater lockout settings? The maximum lockout settings for the pool mode are 90ºF and 104ºF for the Spa mode by default.Turn off your heater, wait a few minutes, then power it back on. If the AO Code persists, move on to the next step. Check the wiring: Inspect the wiring between the blower vacuum switch and the control board. Look for loose connections, damaged wires, or other signs of wear and tear. If you spot any issues, call a professional for assistance.Sep 10, 2023 · Clean the hayward heater regularly to prevent any debris buildup, which can trigger the if code. Remove leaves, sticks, and other objects from the heater. Check the air filter and clean or replace it as needed. A dirty filter restricts airflow and can cause the heater to overheat, resulting in the if code. Start heater again. Does low side pressure drop below 30 psi for R-22 unit or 80 psi on a R-410A unit? Figure C. Replace LP switch. See Note 2 below NO Abandon existing switch on Hayward R-22 units. Replacement switch is a screw on switch. Use a swivel tee on the low side access port. On Summit and R-410A (4T) Hayward units the existing switch ...Be the first to know. Email [email protected] to get notified. Explore Hayward Pool for premium pool equipment, accessories, and supplies. Discover product details on maintenance, filtration, pumps, heaters, cleaners, and chemicals.Check the Gas Valve. Start by ensuring that the gas valve is open and allowing the flow of gas to the pool heater. If the gas valve is closed or partially closed, the heater won’t receive the necessary fuel to ignite. Make sure the valve is fully open and functioning correctly.Description: This recall involves the Hayward UHXNEGVT15001 Negative Pressure 6-inch Vent Kit for pool heaters. The vent kit is used exclusively on the Hayward H500FD Gas Heaters. The kit includes the following: one vent pipe adapter for negative pressure galvanized vent pipe, one flue cover plate with hole for vent, #10 sheet metal screws ...Hayward Pool Heater Lo Code Mother-in-law just installed a heater for her pool, I've never worked on pools but have done my best to research with no avail. I don't believe we need to backwash the system because the pool and heater are both brand new. ... If it still doesn't work call Hayward cuz you could have a bad a pressure/flow sensor ...The heater attempts to light the burner three times before displaying the IF code and shutting down. The code protects the heater from damage caused by a gas buildup or other ignition-related problems. Common Causes of the Hayward Heater IF Code. There are several reasons your Hayward heater may be displaying the IF code.Plaster. Chlorine. Salt Water Generator. SWG Type. Pentair Intellichlor IC-60. Aug 27, 2021. #2. Welcome to TFP. b0 code simple means the heater is being controlled by the remote 2 wire connection to your Prologic and will not respond to the keypad controls.The Hayward H-Series' Finn Plate cupro-nickel heat exchanger has special V-groove design for faster heating and longer life. Hayward Universal H-Series, Low NOx, 250,000 BTU, Propane Gas, Pool and Spa Heater delivers energy efficient heating to your pool's water that you can trust. Hayward Universal H-Series - Versatility & PowerOur network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. ….

With the hayward pool heater p5 code, you can enjoy efficient and reliable heating for your pool. This innovative heater is designed to provide optimal comfort and convenience, allowing you to enjoy your pool all year round. The p5 code feature offers enhanced diagnostics and troubleshooting capabilities, ensuring that any issues can be quickly ...Hi. I have a Hayward H400 natural gas pool and spa heater that is now around 15 years or so old. My kids wanted to use the spa over winter break but the heater was not coming on. I checked it myself and saw it was giving the IF code - ignition failure. I changed modes back to pool, waited for...Dec 13, 2023 · LO CODE FIXES. Step 1: Inspecting the Water Pressure Switch Wiring. Step 2: Testing Water Pressure Switch Continuity. Step 3: Pressure Switch Adjustment (If Required) Step 4: Temperature Limit Switch Wiring Inspection. Step 5: Continuity Test for Temperature Limit Switches. Hayward Heat Pro W3HP21104TC 110,000 BTU Lo Ambient pool heater pump has continuous temperature display, self-diagnostic codes, UV-resistant cabinet. Call Us Nationwide: 1-800-741-9956. ... Hayward W3HP21104TC Pool Heat Pump - Lo Ambient - 110,000 BTU Features & Benefits:Dec 15, 2023 ... If you are getting this HL1 fault code on your Raypak Pool water heater, this video explains what is going on.Key Takeaways. The P5 code on Hayward pool heaters indicates a problem with the pressure switch. Common causes of the P5 code include clogged filters, improper water flow, and electrical issues. Troubleshooting steps for the P5 code involve checking water pressure, inspecting the heat exchanger, and verifying the gas supply.Universal H Series Heaters® Troubleshooting: Hayward H400FDN | Universal H Series Troubleshooting Guide - Page 19 Diagnostic Codes Below is a list of all Diagnostic Codes for the UHS Heater. Troubleshooting Steps for each Code are covered on the following pages. Diagnostic Code AC AO BD CE EE HF HS IF IO LO PF SB SFHayward H-Series H200FD pool heater has 200,000 BTUs equipped with user friendly electronic ignition and capabilities for natural gas and propane. Call Us Nationwide: 1-800-741-9956. ... CODE: ERN152A-8009 / ERLP152A-8009 $ 2,995.00. Raypak R2450ti-E Pool Heat Pump, 48,000 BTU. CODE: R2450ti E Compact $ 2,999.00. Connect With Us. Facebook ... Hayward heater if code, Have a Hayward Pool Heater. Model H250FDP. Have a code "HF" ( Flame Sensor ). Display also showing "service". - Answered by a verified Pool and Spa Expert. We use cookies to give you the best possible experience on our website. ... My Hayward 400K heater has worked intermittently for 1.5 days. It brought pool up to temp, but now, ..., Jun 13, 2020 ... Temperature sensor error , quick vid of changing water pressure switch. Sorry for crapy video no editing system yet., View online or download PDF (6 MB) Hayward H250FD, H350FD, H300FD, H150FD, H400FD, H200FD, Universal H-Series Low NOx User manual • H250FD, H350FD, H300FD, H150FD, H400FD, H200FD, Universal H-Series Low NOx above ground pool accessories PDF manual download and more Hayward online manuals., Our network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools., Hayward pool heater SF temperature Sensor error code. Starts up but turns off and present error code SF. (Part 4) shows heater working and explains how we fi..., May 10, 2022 · Step 5: Clean the filter or remove any obstructions. Examine the position of the valves in the plumbing system. Set the water pressure switch to the desired setting. If the Hayward pool heater LO code persists, the water pressure switch must be replaced. , View online or download Hayward H250FDP Owner's Manual, Troubleshooting Manual ... Brands; Hayward Manuals; Heater; H250FDP; Hayward H250FDP Manuals. Manuals and User Guides for Hayward H250FDP. We have 6 Hayward H250FDP manuals available for free PDF download: Troubleshooting ... Diagnostic Codes and Part Numbers. 19. Troubleshooting Guide. 20 ..., I have a Hayward Pro Heat pump HP13023646 it is 11 months old. Started pool up yesterday, and it fired right up. a few minutes later the code "HP" appeared. the unit shut down for a few seconds and started back up. it runs... you hear it kick in for a few seconds to a minute and then this shut down start up repeats., Our network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools., Enter a postal code to find the nearest Hayward authorized pool professional. Postal Code: How far from the above postal code do you want to search? Enter the miles in the box below. Minimum of 10 miles, maximum of 100. Radius: miles. Pool Type: ... Heaters (not including Heat Pumps) Heat Pumps. Lighting. Pumps. Variable Speed Pumps ..., With the hayward pool heater p5 code, you can enjoy efficient and reliable heating for your pool. This innovative heater is designed to provide optimal comfort and convenience, allowing you to enjoy your pool all year round. The p5 code feature offers enhanced diagnostics and troubleshooting capabilities, ensuring that any issues can be …, How To Read Serial Number & Date Codes Heat Pumps, Heaters*, Filters, Pumps 2005 & Forward (21) 120-402-000002006 Pictured above is the new Hayward ID Tag that will replace our current serial number system. To the left is an explanation of The 6th -8th number will be the year & month. Example: 402=2004, Feb 405 = 2004, May 501 = 2005, Jan 502 ..., The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new or existing pool or spa. An industry leading hydraulic design reduces circulation pump run time to provide energy savings of up to 18% when compared to less efficient competitors., When it comes to hayward heaters, there are some common bd codes that you might encounter. Bd1 indicates ignition failure, which can often be resolved by cleaning the ignition assembly. Bd2 suggests water temperature sensor failure, which can occur due to a faulty sensor or connection issue. If you see bd3, it indicates high limit switch open ..., i puchased a hayward h-series 100,000 btu natural gas heater 8/24/2012 only used it about 2 times in fall and it worked fine. LAST WEEKEND 03/15/13 I RAN FOR ABOUT 24 HOURS AND IT WORKED GREAT WENT TO …, Troubleshooting FS/deF. Normal display when heat pump is in defrost mode. Defrost can occur any time the outdoor ambient temperatures fall into the mid 50's or below. If you have FS/ deF when temps are above mid 50's. This could be an indication the defrost temperature sensor is failing. Check sensor against resistance charts on page 11., Hayward ID Tag that will replace our current serial number system. To the left is an explanation of how to read this number. This ID tag will also list the model number. * Early 1-05 Heat Pumps, Heaters*, Filters, Pumps p, , , p Starting May 1, 2010 and Forward (21) 12-1004-000002006 The 5th -6th number will be the year & the, When ordering parts, include the complete pool heater model number listed on the unit's rating plate, located near the junction boxes on the exhaust side of the heater. (Example: HDF400) All ser- vice must be performed by a qualified technician. View and Download Hayward HDF400 installation & operation manual online., Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support. ... Phase Heaters: 1.0000: Pool Type: In Ground: Product Dimensions: 24 " x 22 " x 29.5 "Product Height: 24 in: Product Length: 29.5 in: Product Weight: 140 lb: Product Width:, Heater will not power up Pages 14-22 Open FC1 and/or FC2 Fuse Pages 23-24 Open FC3 and/or F1 Fuse Pages 25-28 Open FC4 Fuse Pages 29-31 Diagnostic Codes Page 32 BD Code Pages 33-34 EE and CE Codes Page 35 IO and SB Codes Page 36 SF and HS Codes Page 37 ... Hayward Part # FDXLFSKF30 (Qty. 10) Step 1:, 400,000 BTU heating capacity. Fits directly against walls, fences, or other equipment. Competitive heaters require 6–12" wall clearance. Ultra-compact frame for easy drop-in replacement. Dual-fuel tech switches between natural gas and liquid propane. Allows for in-field conversion with a quarter-turn., 9 comments. Best. Add a Comment. ttsignal24 • 1 yr. ago. Remove the Orifice units and see if there is debris inside. Spider webs etc. Tray again. If no go, then you will need to replace main board. It's unlikely that the igniter is bad already, but possible. 3., Heater will not power up Pages 14-22 Open FC1 and/or FC2 Fuse Pages 23-24 Open FC3 and/or F1 Fuse Pages 25-28 Open FC4 Fuse Pages 29-31 Diagnostic Codes Page 32 BD Code Pages 33-34 EE and CE Codes Page 35 IO and SB Codes Page 36 SF and HS Codes Page 37 HS and PF Codes Page 38 HF Code Page 39 LO Code Pages 40-43 , Hi. I just had my pool installed last summer. Now when I tried to start up the heater for the first time this spring I got an Ignition Failure (IF) error., When your Hayward pool heater flashes the 'bo code', it's signaling that there's an issue with the bypass operation. Here's a strategic approach to get your heater back to optimal functionality. Reset the Heater: Turn off the heater and the circuit breaker for 30 seconds. Power up the system again to see if the 'bo code' persists., We have a older Hayward heater that needs something because we have a older Hayward heater that needs something because our pool is small 16 x 28 and it takes a good 6 hours to heat. Live in Henderson NV do we need a new element or can you recommend someone., Pentair Intellichlor IC-60. May 21, 2022. #2. No power switch on the heater. You need to cycle the heater CB to power it down. CE code on the display indicate a display failure. Water gets in around the display and causes the keypad to be non-responsive. The fix is an expensive replacement of the display boards., Hayward ID Tag that will replace our current serial number system. To the left is an explanation of how to read this number. This ID tag will also list the model number. * Early 1-05 Heat Pumps, Heaters*, Filters, Pumps p, , , p Starting May 1, 2010 and Forward (21) 12-1004-000002006 The 5th -6th number will be the year & the, Step 3: From the "Save As" window navigate to the desired USB drive. (Note: please make sure to select the root directory of the USB drive). Step 4: Before saving, change the "Save as type" to "All Files" AND remove the ".txt" file extension that automatically appears. Then click on "Save" button., I have a new Hayward heater. I keep getting a lo code when the pool is turned off. This is a brand new heater and pool. My pool company that installed the pool told me to make sure I'm getting proper water flow in the system. But didn't tell me how to do this. Do I do it on the Hayward..., Adjust the water flow or call a professional if the pressure is too low. Clean the Filter: A dirty or clogged filter can cause Hayward Heater CE Code errors. Clean the filter thoroughly and replace it if necessary. This will improve the heater’s efficiency and prevent future issues. Inspect the Ignition System: If the above steps do not ..., Step 1. Turn off the power supply to the pool heater. Step 2. Wait for at least five minutes to allow the heater to cool down. Step 3. Turn the power back on and press the reset button. This button is typically located near the heater's control panel or on the heater's interior., Meaning of Display Codes 17 Troubleshooting 18 Requesting Assistance or Service 20 Maintenance 21 Winterizing 21 Hayward® Heat Pump Pool Heater Limited Warranty 22 International Warranty 23 Notes 24 Warranty Card Registration 25 Table of contents OWNER'S MANUAL. 2 Thank you for buying